AV















Application : Low voltage thick wall cables for vehicles


Rated Temperature : - 40 °C to + 105 °C(3000 h)

Conductor : Soft annealed plain copper




Insulation : Class B (105°C) PVC and RoHS Compliant




Standard : JASO C 3406






















Conductor Insulation Cable
Nominal Number of wires Conductor Max. resistance Insulation thickness Outside diameter Weight
cross-section and max. diameter max. diameter at 20 °C nom. min. nom. max. approx.
(mm²) (no x mm) (mm) (mΩ/m) (mm) (mm) (mm) (mm) (kg/km)
0.5 7 x 0,32 1.00 32.70 0.60 0.48 2.20 2.40 10
0,5 f 20 x 0,18 1.00 36.70 0.60 0.48 2.20 2.40 9
0,75 f 30 x 0,18 1.10 24.40 0.60 0.48 2.40 2.60 12
0.85 11 x 0,32 1.20 20.80 0.60 0.48 2.40 2.60 13
1.25 16 x 0,32 1.50 14.30 0.60 0.48 2.70 2.90 18
1,25 f 50 x 0,18 1.50 14.70 0.60 0.48 2.70 2.90 17
2 26 x 0,32 1.90 8.81 0.60 0.48 3.10 3.40 26
2 f 37 x 0,26 1.80 9.50 0.60 0.48 3.00 3.40 25
3 41 x 0,32 2.40 5.59 0.70 0.56 3.80 4.10 40
3 f 61 x 0,26 2.40 5.76 0.70 0.56 3.80 4.10 40
5 65 x 0,32 3.00 3.52 0.80 0.64 4.60 4.90 60
8 50 x 0,45 3.70 2.32 0.90 0.72 5.50 5.80 90
10 63 x 0,45 4.50 1.84 1.00 0.80 6.50 6.90 120
15 84 x 0,45 5.40 1.38 1.10 0.88 7.60 8.00 150
20 41 x 0,80 6.10 0.887 1.10 0.88 8.30 8.80 220
30 70 x 0,80 8.00 0.520 1.40 1.12 10.80 11.50 380
40 85 x 0,80 8.60 0.428 1.40 1.12 11.40 12.10 455
50 108 x 0,80 9.80 0.337 1.60 1.28 13.00 13.80 580